Troubleshooting
ORiNOCO® 802.11n Access Points - Software Management Guide 130
8.2 Connectivity Issues
Connectivity issues include any problem that prevents you from powering up or connecting to the device.
There is No Data
Link Established
Verify that the indicator on the device port is “ON.”
Verify that the PoE Injector hub is properly connected to the ethernet port of the
device.
Verify that the ethernet cable is Category 5 or better and is less than 100 meters
(approximately 325 feet) in length from the ethernet port of the device to the PoE.
Try to connect a different device to the same port on the PoE Injector hub – if it works
and a link is established then there is probably a fault in the data link of the device.
Try to re-connect the cable to a different output port (remember to move the input
port accordingly) – if it works then there is a fault probably in the output or input port
of the PoE Injector hub or a bad RJ45 connection.
Power Overload
Indications
Connect the device to a PoE Injector.
Ensure that there is no short over on any of the connected cables.
Move the device into a different output port (remember to move the input port
accordingly) - if it works then there is a fault probably in the previous RJ45 port or bad
RJ45 port connection.
Problem Solution
Device Does Not
Boot / No LED
Activity
See The Device Does Not Boot / Power ON / Initialize
Ethernet Link Does
Not Work
Check the ethernet LED. The color of the Ethernet LED indicates the speed of the Ethernet
traffic:
Try connecting the device:
To a different port on the PoE and/or a switch.
Through a different Ethernet Category 5/Category6 cable.
Ethernet LED Color Speed
Red 100 Mbps
Green 1000 Mbps
OFF No link is available or Ethernet is not connected